UKAS Pipette Calibration

We can offer UKAS Pipette Calibration on all leading manufacturers of pipettes

If you just need an indication of our service & calibration charges at this stage. Take a few seconds to complete an estimate request.

Estimate->

Request a onsite or back to base quotation.

Onsite or Back to Base Quotation->

Levels of UKAS Pipette Calibration

Service Level: UKAS PA

Full Post Adjustment calibration.

  • Pipette is serviced and adjusted where applicable.
  • Full Post Adjustment Calibration performed. A series of  repetitive pipettings at points through out the range of the pipette (as determined by the required test plan). On multi-channel pipettes, each channel will be calibrated individually without the other channels being aspirated. Calculation of the uncertainty of measurement. UKAS certificate Issued.

Service Level: UKAS AF/PA

Full As Found + Post Adjustment calibration.

  • Full As Found Calibration performed. A series of repetitive pipettings at points through out the range of the pipette (as determined by the required test plan). On multi-channel pipettes, each channel will be calibrated individually without the other channels being aspirated. Calculation of the uncertainty of measurement. UKAS certificate issued.
  • Pipette is serviced and adjusted where applicable.
  • Full Post adjustment Calibration performed. A series of repetitive pipettings at points through out the range of the pipette (as determined by the required test plan). On multi-channel pipettes, each channel will be calibrated individually without the other channels being aspirated. Calculation of the uncertainty of measurement. UKAS certificate issued.

Service Level: UKAS AF

Full As Found calibration.

  • Full Post adjustment Calibration performed. A series of repetitive pipettings at points through out the range of the pipette (as determined by the required test plan). On multi-channel pipettes, each channel will be calibrated individually without the other channels being aspirated. Calculation of the uncertainty of measurement. UKAS certificate issued.
  • Equipment will not be serviced or adjusted or Post Adjustment calibration performed unless requested by the customer (additional charge applies).

Levels of Calibration

UKASCal 3.10 - UKAS Pipette Calibration

Service includes cleaning, servicing, a full range performance check, and a UKAS Certificate of Calibration.

Type Num. Of Readings Test Points
Single 10 10 @ Nominal
Multi-Range 30 10 @ Mid / Min / Max
Electronic Pipette 30 10 @ Mid / Min / Max
MultiPette 30 10 @ Mid / Min / Max
Multi 8 Channel 240 10 / Chan @ Mid / Min / Max
Multi 12 Channel 360 10 / Chan @ Mid / Min / Max
Multi 16 Channel 480 10 / Chan @ Mid / Min / Max
Dispenser 30 10 @ Mid / Min / Max
EDOS 30 10 @ Mid / Min / Max

About Your UKAS Pipette Calibration Certificate

Certificate of Calibration

This document is issued in accordance with our UKAS accreditation 0438 and consists of at least two pages. Page 1 shows the customer and instrument details, calibration date and method of calibration. Page 2 and further pages will detail the actual calibration data, the details of which are detailed below, it may also detail the laboratory environmental conditions depending on the type of instrument.

Calibration Type

The certificate will be identified (A) ‘As Found‘ or (B) ‘ Post Adjustment‘. We will only use B when we have actually changed the calibration of the equipment. You may require both types to show the history of your instrument.

Environmental Monitoring

The Temperature, Humidity and Barometric Pressure will be monitored during the calibration.

Test Equipment

European Instruments will provide a suitable electronic balance, which has been calibrated at the place of use, suitably generated water for the calibration and calibrated environmental monitoring equipment.

Uncertainty of Measurement

This is calculated in accordance with an approved formula taking into account the following:

  • The pooled standard deviation of the technician carrying out the calibration.
  • The performance and resolution of the weighing equipment used.
  • The performance of the pipette at the time of calibration.

If you just need an indication of our service & calibration charges at this stage. Take a few seconds to complete an estimate request.

Estimate->

Request a onsite or back to base quotation.

Onsite or Back to Base Quotation->